| Output signal | 0...10 V |
| Accuracy: Incl. Non-Linearity, Hysteresis, Repeatability, Zero-offset and Final-offset (acc. to IEC 61298-2) | < ±0.5% FSO |
| Pressure range: The operating pressure range is intended from 0.5% to 100% FS | 0...200 bar |
| Resolution | Infinite |
| Overpressure (without degrading performance) | 400 bar |
| Pressure containment (burst test ) | 600 bar |
| Pressure Media | Fluid compatible with Stainless Steel |
| Housing | Stainless Steel |
| Power supply | 12...32 Vdc |
| Dielectric strenght | 350 Vdc |
| Zero output signal | 0 V (nominal) |
| Full scale output signal | 10 V (nominal) |
| Long term stability | < 0.2% FSO/ per year |
| Operating temperature range (process) | -40...+125°C (-40...+257°F) |
| Operating temperature range (ambient) | -40...+105°C (-40...+221°F) |
| Compensated temperature range | -20...+85°C (-4...+185°F) |
| Storage temperature range | -40...+125°C (-40...+257°F) |
| Temperature effects over compensated range (zero-span) | ± 0.015% FSO/°C typical ± 0.02% FSO/°C max. |
| Response time (10...90%FSO) | < 1 msec. |
| Warm-up time: Time within which the rated performance is achieved | < 30 sec. |
| Mounting position effects | Negligible |
| Humidity | Up to 100%RH non-condensing |
| Weight | 80-120 gr. nominal |
| Mechanical shock | 1000g according to IEC 68-2-32 |
| Vibrations | 20g according to IEC 68-2-6 and IEC 68-2-36 |
| Ingress protection | sealed to IP65/IP67 |
| Output short circuit and reverse polarity protection | YES |
| CE Conformity | EC Directive 2004/108/CE |